Short Answer
Export your model with the unit of measure set to "meter" and without IfcBuildingElementProxy elements. Disable the option "Split multi-layer building elements into individual elements". Also make sure that elements and attributes allow a clear identification of the building component.
When to Use This
These recommendations apply whenever you export a model from your CAD software.
Step-by-Step Instructions
- Set the unit of measure in the export to "meter".
- Do not export any IfcBuildingElementProxy elements.
- Disable the option "Split multi-layer building elements into individual elements".
- Make sure that elements and attributes allow a clear identification of the respective building component.